Incubator ,with special designed heating method has very good temperature uniformity even without fan inside, can also prevent the culture solution from being blown dry. Incubator is a widely used incubator.
Model | FN-105 (N)-43D | FN-105 (N)-63D | FN-105 (N)-124D | FN-105 (N)-209D | |
FN-105 (N)-43L | FN-105 (N)-63L | FN-105 (N)-124L | FN-105 (N)-209L | ||
Performance | Temp. range | RT+5-65°C | RT+5-65°C | RT+5-65°C | RT+5-65°C |
Performance | Temp. Resolution | 0.1°C | 0.1°C | 0.1°C | 0.1°C |
Performance | Temp. fluctuation | ± 5°C | ± 5°C | ± 5°C | ± 5°C |
Performance | Temp accuracy | ± 1°C | ± 1°C | ± 1°C | ± 1°C |
Structure | Chamber Material | Mirror Stainless steel | Mirror Stainless steel | Mirror Stainless steel | Mirror Stainless steel |
Structure | External Material | Spraying Cold rolled steel | Spraying Cold rolled steel | Spraying Cold rolled steel | Spraying Cold rolled steel |
Structure | Thermal insulation material | PU | PU | PU | PU |
Structure | Heater | Heating tube | Heating tube | Heating tube | Heating tube |
Structure | Rated power | 0.25 KW | 0.25 KW | 0.5 KW | 0.6 KW |
Structure | Air Outlet | Inner diameter Ø28mm+1 top | Inner diameter Ø28mm+1 top | Inner diameter Ø28mm+1 top | Inner diameter Ø28mm+1 top |
Structure | Additional | Fluorescent lamp (L model): UV (L Model): gas inlet (L Model) | Fluorescent lamp (L model): UV (L Model): gas inlet (L Model) | Fluorescent lamp (L model): UV (L Model): gas inlet (L Model) | Fluorescent lamp (L model): UV (L Model): gas inlet (L Model) |
Controller | Temp. Control | PID Control | PID Control | PID Control | PID Control |
Controller | Temp. Display | D: 4 digital LED display L: LCD display | D: 4 digital LED display L: LCD display | D: 4 digital LED display L: LCD display | D: 4 digital LED display L: LCD display |
Controller | Timer | 0~9999 Minutes | 0~9999 Minutes | 0~9999 Minutes | 0~9999 Minutes |
Controller | Sensor | Pt100 | Pt100 | Pt100 | Pt100 |
Controller | Additional | RS 485 (L Model) | RS 485 (L Model) | RS 485 (L Model) | RS 485 (L Model) |
Safety Device | Over-temperature alarm: independent limiter (L model) | Over-temperature alarm: independent limiter (L model) | Over-temperature alarm: independent limiter (L model) | Over-temperature alarm: independent limiter (L model) | |
Specification | Inner (W×D×H)/mm | 350x350x350 | 400x350x450 | 500x450x550 | 600x580x600 |
Specification | Exterior (W×D×H)/mm | 500x475x615 | 550x475x715 | 650x575x815 | 750x505x865 |
Specification | Packing (W×D×H)/mm | 641X610X781 | 691X610X881 | 791X710X981 | 891X840X1031 |
Specification | Capacity | 43L | 63L | 124L | 209L |
Specification | Shelf load-bearing | 15KG | 15KG | 15KG | 15KG |
Specification | Shelf number | 2(standard) | 2(standard) | 2(standard) | 2(standard) |
Specification | Voltage | AC220V/1.1A | AC220V/1.1A | AC220V/2.3A | AC220V/2.7A |
Specification | NW/GW | 29/32kg | 33/38kg | 49/53kg | 62/67kg |
Optical device | shelf | shelf | shelf | shelf |